The HPC ready-to-finish rectangular trough fire pit pairs a narrow recessed linear insert with an unfinished enclosure for a custom outdoor feature. Its 60″ × 24″ enclosure provides a broad surrounding surface for compatible decorative cladding while keeping the fire area in a clean, elongated trough.
Choose the 36″ or 48″ Torpedo trough insert configuration with the available natural-gas or liquid-propane ignition system. The selector length identifies the insert, not the enclosure. Electronic On/Off, push-button flame-sensing and match-lit models have distinct operating and supply requirements.
HPC provides a three-year limited warranty on ready-to-finish enclosures, with component-specific insert coverage including lifetime coverage on stainless-steel fire burners. Final facing, approved media and installation are separate.
Dimensions and Configuration
Enclosure: 24″ W × 60″ L × 18″H before decorative cladding.
Insert: Selected 36″ or 48″ Torpedo trough configuration.
Construction: Unfinished cement backer panels with steel bracing, intended for compatible outdoor decorative finish materials.
What's Included
The selected unfinished enclosure, matched trough insert and operating system. Decorative cladding, approved media, site preparation and installation are separate.
Installation and Compatibility
Match natural gas or liquid propane to the installed supply. Electronic On/Off choices require the selected 120 VAC or 24 VAC supply; push-button and match-lit versions follow their dedicated battery or manual ignition instructions.
A qualified professional must establish gas capacity, pressure, support, clearances, utility connections, drainage, ventilation and service access for the exact model. Complete control and cladding openings without blocking required air paths. A drawing for an H-burner enclosure is not a substitute for the selected trough configuration.
Care and Maintenance
Allow the system to cool before cleaning or covering. Keep ignition components, drains and ventilation clear, maintain the chosen decorative finish correctly, and follow the selected insert manual's inspection and service requirements.
Manuals and Resources
Installation Manual — Electronic On/Off — 120 VAC: View PDF
Installation Manual — Push Button / Flame Sensing: View PDF
Installation Manual — Match Lit: View PDF
Frequently Asked Questions
How do I know how much fire glass or lava rock I need?
Review the media included with your selected configuration before adding extras. Use our Fire Glass & Lava Rock Calculator to estimate the amount from the inside media area and the manufacturer-approved fill depth. Follow the exact selected appliance or insert instructions for approved media, required quantity and placement. Ceramic river rock is decorative topping rather than bulk base fill; the calculator does not determine its piece count.
Does the 36″ or 48″ option give the outside enclosure length?
No. It identifies the trough insert. The nominal enclosure is 24″ W × 60″ L × 18″H before final decorative finishing.
What makes a trough configuration different?
It uses a narrow recessed linear pan and straight burner rather than a wider H-burner insert. The opening and support details must match the trough configuration.
Which burner family is offered here?
The offered configurations use Torpedo trough inserts. Select the complete length, ignition and fuel combination for the project.
Is the decorative finish already applied?
No. The cement-board enclosure is unfinished for compatible outdoor cladding. Decorative materials and finishing labor are separate.
What is included with the kit?
The selected enclosure, matched trough insert and operating system are included. Approved media, final cladding and site installation are separate.
Can it connect to either natural gas or propane?
Order the exact natural-gas or liquid-propane configuration for the installed supply. Do not interchange fuels or assume a small-tank kit is included.
What power does electronic ignition need?
Electronic On/Off versions require the selected 120 VAC or 24 VAC supply. They are not Hi/Lo controls, and their power requirements are not interchangeable.
Do the other ignition systems use mains power?
Push-button flame-sensing models use their specified battery ignition procedure. Match-lit models use manual lighting instructions. Follow the exact configuration's manual.
Can I use an H-burner enclosure drawing?
No. The trough insert has a different opening, support and control layout. Plan the installation around the exact selected trough configuration.
Can I cover air openings with finish materials?
No. Maintain all required ventilation, drainage and service access. A qualified installer must coordinate the decorative finish with the gas-system requirements.
Can I burn wood or cook over the trough?
No. It is a decorative outdoor gas fire feature, not a wood-burning fire starter or cooking appliance.
What media and care are required?
Use only approved media at the depth and arrangement specified by the selected manual. Keep the ignition area, drains and air openings clear, and let the system cool before cleaning or covering.
What warranty applies?
The unfinished enclosure carries three-year limited coverage. Stainless-steel fire burners have lifetime coverage. For components fitted to the selected ignition system, residential coverage is three years on electronic components and gas valves, two years on pilot assemblies and five years on other stainless-steel components; corresponding commercial coverage is one year.
What conditions apply to warranty coverage?
Coverage begins with the original sale or shipment from HPC and addresses qualifying manufacturing defects. Overheating, modification, abuse, improper storage, installation and maintenance are excluded. Covered work is limited to parts and in-house labor; field installation and maintenance labor are not included.
How do I request warranty service?
Warranty claims are handled through CUI Heat. Keep the original purchase information, model details and photographs. Obtain manufacturer return authorization before sending a defective product; the authorization must remain valid when the return is received.
Is shipping free?
Free shipping applies on most orders within the continental U.S. Oversized freight and certain destinations may have additional charges disclosed before purchase.
When will my order arrive?
Timing depends on product availability, destination and carrier. Estimates are not guaranteed delivery dates. Freight carriers may contact you to arrange an appointment.
What should I do if it arrives damaged?
Photograph the product and packaging, report damage within 48 hours of delivery and retain the packaging until the issue is resolved.
Does delivery include assembly or installation?
Unless expressly included in the order documentation, delivery does not include assembly, installation, indoor placement, packaging removal or removal of an existing product.
Can I return an installed or used product?
Standard returns require authorization within 30 days of delivery and an unused item with original packaging and accessories. Used or installed items are excluded unless defective on arrival. Customized, made-to-order and special-order products are excluded.
What costs can apply to an approved return?
Approved returns generally carry a 25% restocking fee and customer-paid return shipping. Damage reported within 48 hours and same-item exchanges are exempt from the restocking fee; defective or damaged items are exceptions to customer-paid return shipping.
Who services this product?